In a world without FaceTime, Zoom, and other screen sharing tools Jason Langer learned to communicate well out of necessity. Nerd Journey # 218 - Explaining Hard Concepts in Simple Terms with Jason Langer Best Practices & General IT.Did the Snipping tool usurp the print screen key? Windowsĭid one or some of the recent Windows 11 updates alter how the print-screen button is bound? Been using Snagit for many years and just recently I started getting the Windows Snipping tool instead of Snagit when I push the print screen button.In the end.Snap! - Wooden Satellite, Bioactive Ink, Body Part Repossession, Smart Ring Spiceworks Originalsįlashback: June 5, 1977: The original Apple II computer goes on sale (Read more HERE.)īonus Flashback: June 5, 1979: Council recommends full scale development of the Global Pos.Say you get a new employee who literraly has trouble naviating windows operating system, has trouble printing even!is this IT's job to act as a professor or would you bring this up to there management?At times i think, how the heck did they hire this pers. Is it IT's Job to hold hands for Non-IT workers? Software.Open neutrals can do a lot of damage very quickly! I bet one of the houses had a neutral open up, and suddenly the cabling was carrying the neutral current. It is also secure, and immune to interference.ĬharlesHTN, that was more than just a ground potential problem. Fiber is much more permanent, reliable, and can carry much more data. Finally, have the termination work professionally done.Īs far as using a radio system, I would not, unless there was no other way to do this. Seek advice from a contractor (or have them do the work) of how many pull boxes you need on that run. It is much more rugged, and 1200 feet is a long pull. Use direct burial cable, even if run in conduit. I would run a cable with half a dozen fibers or more, as the incremental cost of extra fibers in a cable is minimal. I would go with single mode fiber, although multi mode will work fine at that distance as well. It will be worth the extra cost in the long run (literally and figuratively). Suffice it to say, the warning of ground potential differences is VERY real. Thankfully, the PC's themselves survived. A Dell docking station also on that switch was killed too. I never got to see what the connected equipment looked like, suffice it to say, they had to replace it. I *think* this was a coupler they had used, not really sure WHAT it was: Within a few weels, they had a BAD storm, and heard a loud POP. I knew and warned about this potential issue, but the install happened anyway (was just needed short term, and had already bought the parts). This past summer, some folks I know ran 2x Cat6 between two houses (network on one, phone on another). Yup.always heard that, recently, I saw it. Justin_Mc wrote:More importantly, the two buildings will have different electrical grounds, which means you could have a current running through the grounds on your equipment on both ends-frying gear (and possibly - though unlikely-people).(this is also one of the reasons you use pvc conduit) Also, a lightning strike on one building would likely fry gear in both buildings with copper.Įdit: Here's an article I found. This is what should be done, what will be done may be a little or a lot different.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |